Universal
any rotary system
A glide path is followed, not created
Every canal already contains a path to the apex: the space the pulp once occupied. T-Glide opens that natural path incrementally, so your primary shaping files can follow the tooth's own anatomy.
Key features
AF-L wire technologyFlexible NiTi that respects canal anatomy.
Inactive tipAdvanced tip processing to help avoid forming steps.
Directional endo stopMarks canal length and shows the file's bending direction.
Precision manufacturingAutomated production for cyclic fatigue resistance and efficiency.
Why establish a glide path?
Without a glide path
File separation · Primary files meet unprepared walls under maximum torsional and cyclic stress.
Ledge formation · A file tip binding against the wall under torque can form a ledge.
Canal transportation · Files forced off the natural path straighten curved canals.
Apical blockage · Debris compacted ahead of an unguided file can block the apical third.
Inadequate cleaning · Tissue and bacteria left in the most critical apical zone.
With a glide path
Safe file tracking · Primary files follow an established path with less wall engagement and torsional load.
Lower ledge risk · The path is opened before primary files enter, so the tip isn't forced against the wall.
Anatomy preserved · Incremental .02 enlargement respects the canal curvature.
Predictable apical prep · A #19/.02 glide path gives primary files a known, reproducible channel.
Better outcomes · Research links mechanical glide paths with less postoperative pain, less transportation and fewer separations.
When to use a rotary glide path
Insert a #10 K-file. Does it pass passively to the estimated working length without apical pressure?
Scenario A
#10 K-file: passes freely
Direct shaping
Reaches full WL passively, no apical pressure.
- Straightforward anatomy
- Minimal curvature
- e.g. straight, wide anterior tooth
>Proceed to primary shaping.
Scenario B
#10 K-file: partial
Hand-file glide path
#10 reaches WL with effort; #15 with watch-winding.
- Mild to moderate curvature
- Some hand-file negotiation
- e.g. premolar, single-rooted tooth
> #15 loose at WL, then primary shaping.
Scenario C
#10 K-file: can't reach WL
Rotary glide path
Resistance before the apex; long, curved or calcified canal.
- Multi-planar curvature or calcification
- Long canals (>25 mm), complex molars
- e.g. curved mesial molar, calcified premolar
> T-Glide #13 > #16 > #19, then primary shaping.
The golden rule: the #10 K-file must be loose at EVERY level before T-Glide is introduced at that level. The glide path file follows the hand file; it never leads it.
The incremental glide path protocol
1Orifice & coronal access
Remove the dentine triangle with an orifice opener, Gates Glidden or brushing rotary to gain straight-line access into the root.
2Hand file: incremental advance
Advance the #10 K-file passively to 1 mm short of any resistance, irrigate with NaOCl, then advance 1 mm further. Repeat until the #10 is loose at working length. Pre-curve for multi-planar canals.
3T-Glide #13/.02 follows the hand file
Introduce #13 only to the depth already confirmed by the hand file. Use short 2 - 3 mm in-out strokes at 300 rpm with NaOCl in the canal. Repeat until #13 reaches full WL passively.
4#16, then #19: same rule
Each size follows the same incremental rule, with the #10 K-file loose at WL before the next size is introduced. When all three reach WL passively, the canal is ready for primary shaping.
T-Glide files
#13/.02Step 1
Opens the initial glide path
- Enter only where #10 is already loose
- Short 2 - 3 mm in-out strokes
- Irrigate after every 3 strokes
21 mm · F212602021013
25 mm · F212602025013
#16/.02Step 2
Enlarges to an intermediate size
- Introduce only after #13 reaches WL
- Check endo stop orientation
- Recapitulate with #10 after each pass
21 mm · F212602021016
25 mm · F212602025016
#19/.02Step 3
Completes the glide path
- Confirms canal ready for primary shaping
- Verify WL with an apex locator
- Final NaOCl + EDTA irrigation
21 mm · F212602021019
25 mm · F212602025019
Specifications & motor settings
WireAF-L NiTi
TaperFixed .02
Sizes#13, #16, #19
Lengths21 mm, 25 mm
MotionContinuous rotation
Speed300 rpm
Torque1.8 - 2.0 N·cm
Files per box6
Key clinical tips
- NaOCl throughout: Establish and enlarge the glide path with NaOCl present at all times to prevent blockage and start disinfection.
- #10 K-file loose first: The #10 must be loose at every level before a #15 or any NiTi file is introduced there.
- Pre-curve for curved canals: Pre-curve hand files to scout curved or multi-planar canals. T-Glide follows where the hand file has been.
- Resistance? Open coronally: If the #10 meets resistance before WL, open the coronal region first, then try to advance again.
- Conservative access: Uncover all canals and gain straight-line access while preserving pericervical dentine.
- Confirm at every step: Check WL with an apex locator after every T-Glide size. WL can shift as the glide path opens.
Bulk savings
Mix & Match Discount
Combine any rotary files across our range, including T-Glide. Discounts apply automatically as you add to your cart.
super value
Buy 40+
20%
OFF
Ready for primary shaping
T-Glide is compatible with all rotary systems. Once #19/.02 reaches working length passively, continue with your preferred primary shaping system.
For dental professionals only. This information is general in nature and is not a substitute for professional clinical judgement.