Key distinction
AF CL is not a shaping file. It is a precision bypass instrument, used to cross a ledge and re-establish access to working length before standard shaping continues.
Why ledges need a dedicated solution
NiTi shape memory pushes a file against the outer wall of a curve. Cut too hard and it forms a ledge, usually at the point of maximum curvature or in the apical third. Once it forms, a standard straight-tipped file catches on the ledge shoulder and just deepens it.
Apical tissue left untreatedBacteria, tissue and biofilm persist below the ledge.
Canal transportationRepeated attempts with standard files drift away from the original path.
Risk of perforationEach pass deepens the ledge towards the outer root surface.
Treatment failureA canal that can't reach working length can't be properly obturated.
Key features
Pre-bent tipThe defining feature. Inserted by hand, the bend deflects the tip away from the ledge shoulder towards the original canal. A straight tip can't do this.
AF-R wire technologyHeat-treated NiTi for flexibility and cyclic fatigue resistance under the unusual loads at a ledge.
Rectangular cross-sectionRigidity where it's needed, with multiple cutting edges that break down the ledge shelf with each cycle.
Depth marks: 18 · 19 · 20 · 22 mmTrack exactly how far the tip has travelled during manual insertion, relative to the estimated ledge depth.
The two-phase bypass technique
- Remove the motor handpiece and insert AF CL #10 by hand.
- The pre-bent tip deflects away from the ledge towards the original canal wall.
- Advance with a slow, light watch-winding motion until the tip passes below the ledge.
- If resistance increases, withdraw 1 mm, re-angle the tip and re-advance.
No motor. Hand only. The tip does the work.
Phase 2
Reciprocating removal
- Attach the endo motor with the file already past the ledge.
- Select the reciprocating programme (see motor settings below).
- Use very short 1 - 3 mm in-out strokes to gradually remove the ledge shelf.
- Irrigate every few strokes to clear debris from the ledge site.
Motor only after manual bypass is confirmed.
Critical sequence: ALWAYS bypass manually first. NEVER engage the motor before the file tip has passed the ledge by hand. The reciprocating motion removes the ledge; it cannot replace manual bypass.
Clinical protocol
1Diagnose & plan
Review radiographs and CBCT (if available) to locate the ledge and estimate its depth and direction. Establish straight-line access and irrigate with NaOCl.
2Attempt a hand-file bypass
Pre-curve a #10 K-file towards the inner wall and use a light watch-winding motion. If it crosses the ledge, confirm working length and reshape as normal. If not, introduce AF CL.
3AF CL Phase 1: manual insertion
Insert AF CL #10 by hand, using the depth marks to track how far the tip has travelled relative to the ledge.
4AF CL Phase 2: reciprocating
Once the tip is confirmed below the ledge, attach the motor and remove the shelf with short strokes. Repeat through #15, #20, #25 and #30.
5Confirm WL & re-shape
Confirm working length with an apex locator and periapical radiograph, recapitulate with a #10 K-file, irrigate with NaOCl and EDTA, then re-shape with your primary rotary system.
Size progression
Colour-coded sizes, used in order. Recapitulate with a #10 K-file and confirm working length between each one.
Step 1 · Initial bypass. Start here for all ledge cases.
Step 2 · First enlargement once #10 has confirmed the bypass to WL.
Step 3 · Intermediate enlargement that smooths the bypass path.
Step 4 · Near full size. The path should be smooth and clear.
Step 5 · Final size. Completes the bypass, ready for primary shaping.
Specifications & motor settings
WireAF-R NiTi
Tip designPre-bent
Cross-sectionRectangular
Depth marks18 / 19 / 20 / 22 mm
MotionReciprocating CW 90° / CCW 30°
Speed150 - 300 rpm
Torque2.0 N·cm
Files per pack6
Use TruMotor+ or any compatible reciprocating endo motor.
Available packs
AF CL #10 · 21 mm
Ref. F072606021010
AF CL #10 · 25 mm
Ref. F072606025010
Kit #10 - #30 · 21 mm
Ref. F071600021000
Kit #10 -#30 · 25 mm
Ref. F071600025000
Tips for success
- Only reach for AF CL when a pre-curved #10 K-file can't get past the ledge.
- Point the pre-bent tip towards the inner wall of the curve, where the original canal runs.
- Work through all five sizes. Stopping at #10 or #15 leaves a narrow, irregular path.
- After each size, recapitulate with a #10 K-file, irrigate, and re-confirm working length with the apex locator.
- In retreatment, remove as much gutta-percha as possible with retreatment files first. GP remnants make it harder for AF CL to find the original path.
Bulk savings
Mix & Match Discount
Combine any rotary files across our range, including AF CL.
Discounts apply automatically as you add to your cart.
super value
Buy 40+
20%
OFF
Continue shaping
Once all five AF CL sizes reach working length, re-shape the canal with one of our rotary or reciprocating systems.
For dental professionals only. This information is general in nature and is not a substitute for professional clinical judgement.